1,377 research outputs found

    Wearable technology for spine movement assessment: A systematic review

    Get PDF
    Continuous monitoring of spine movement function could enhance our understanding of low back pain development. Wearable technologies have gained popularity as promising alternative to laboratory systems in allowing ambulatory movement analysis. This paper aims to review the state of art of current use of wearable technology to assess spine kinematics and kinetics. Four electronic databases and reference lists of relevant articles were searched to find studies employing wearable technologies to assess the spine in adults performing dynamic movements. Two reviewers independently identified relevant papers. Customised data extraction and quality appraisal form were developed to extrapolate key details and identify risk of biases of each study. Twenty-two articles were retrieved that met the inclusion criteria: 12 were deemed of medium quality (score 33.4-66.7%), and 10 of high quality (score> 66.8%). The majority of articles (19/22) reported validation type studies. Only 6 reported data collection in real-life environments. Multiple sensors type were used: electrogoniometers (3/22), strain gauges based sensors (3/22), textile piezoresistive sensor (1/22) and accelerometers often used with gyroscopes and magnetometers (15/22). Two sensors units were mainly used and placing was commonly reported on the spine lumbar and sacral regions. The sensors were often wired to data transmitter/logger resulting in cumbersome systems. Outcomes were mostly reported relative to the lumbar segment and in the sagittal plane, including angles, range of motion, angular velocity, joint moments and forces. This review demonstrates the applicability of wearable technology to assess the spine, although this technique is still at an early stage of development

    Exploring the role of wearable technology in sport kinematics and kinetics: a systematic review

    Get PDF
    The aim of this review was to understand the use of wearable technology in sport in order to enhance performance and prevent injury. Understanding sports biomechanics is important for injury prevention and performance enhancement and is traditionally assessed using optical motion capture. However, such approaches are limited by capture volume restricting assessment to a laboratory environment, a factor that can be overcome by wearable technology. A systematic search was carried out across seven databases where wearable technology was employed to assess kinetic and kinematic variables in sport. Articles were excluded if they focused on sensor design and did not measure kinetic or kinematic variables or apply the technology on targeted participants. A total of 33 articles were included for full-text analysis where participants took part in a sport and performed dynamic movements relating to performance monitored by wearable technologies. Inertial measurement units, flex sensors and magnetic field and angular rate sensors were among the devices used in over 15 sports to quantify motion. Wearable technology usage is still in an exploratory phase, but there is potential for this technology to positively influence coaching practice and athletes’ technique

    Predicting knee osteoarthritis risk in injured populations

    Get PDF
    Background Individuals who suffered a lower limb injury have an increased risk of developing knee osteoarthritis. Early diagnosis of osteoarthritis and the ability to track its progression is challenging. This study aimed to explore links between self-reported knee osteoarthritis outcome scores and biomechanical gait parameters, whether self-reported outcome scores could predict gait abnormalities characteristic of knee osteoarthritis in injured populations and, whether scores and biomechanical outcomes were related to osteoarthritis severity via Spearman's correlation coefficient. Methods A cross-sectional study was conducted with asymptomatic participants, participants with lower-limb injury and those with medial knee osteoarthritis. Spearman rank determined relationships between knee injury and outcome scores and hip and knee kinetic/kinematic gait parameters. K-Nearest Neighbour algorithm was used to determine which of the evaluated parameters created the strongest classifier model. Findings Differences in outcome scores were evident between groups, with knee quality of life correlated to first and second peak external knee adduction moment (0.47, 0.55). Combining hip and knee kinetics with quality of life outcome produced the strongest classifier (1.00) with the least prediction error (0.02), enabling classification of injured subjects gait as characteristic of either asymptomatic or knee osteoarthritis subjects. When correlating outcome scores and biomechanical outcomes with osteoarthritis severity only maximum external hip and knee abduction moment (0.62, 0.62) in addition to first peak hip adduction moment (0.47) displayed significant correlations. Interpretation The use of predictive models could enable clinicians to identify individuals at risk of knee osteoarthritis and be a cost-effective method for osteoarthritis screening

    Histological and immunohistochemical evaluation of mandibular bone tissue regeneration

    Get PDF
    The purpose of the study was to perform an immunohistochemical and histological evaluation of samples taken from different bone regeneration procedures in atrophic human mandible. 30 patients (15 men and 15 women, age range of 35-60 years), non-smokers, with good general and oral health were recruited in this study and divided into three groups. The first group included patients who were treated with blood Concentration Growth Factors (bCGF), the second group included patients who were treated with a mixture of bCGF and autologous bone, while the third group of patients was treated with bCGF and tricalcium phosphate/hydroxyapatite (TCP-HA). Six months after the regenerative procedures, all patients undergone implant surgery, and a bone biopsy was carried out in the site of implant insertion. Each sample was histologically and immunohistochemically examined. Histological evaluation showed a complete bone formation for group II, partial ossification for group I, and moderate ossification for group III. Immunohistochemical analysis demonstrated a statistically significant difference between the three groups, and the best clinical result was obtained with a mixture of bCGF and autologous bone

    Monolithic zirconia and digital impression: case report

    Get PDF
    The aim of this study is to present a clinical case of a full arch prosthetic rehabilitation on natural teeth, combining both digital work-flow and monolithic zirconi

    Breast tuberculosis: A case report of primary type mammary tuberculosis

    Get PDF
    Mammary tuberculosis is exceptional in developed countries. It can mimic an abscess or a granulomatous mastitis. In subjects coming from endemic areas, it is necessary to suspect a tuberculosis infection in case of recurrent mastitis refractory to antibiotics. Positivity of Quantiferon-TB Gold assay can help to confirm the clinical suspicion

    Uncommon differential diagnosis of a breast ulcer: A case study

    Get PDF
    Introduction: Spider bites are common worldwide. Frequently symptoms resolve without any adverse outcome, but in rare cases the bite can cause severe morbidity. The most typical presentation of Mediterranean recluse spider (Loxosceles Rufescens) bite is a dermatonecrotic lesion of the skin (skin loxoscelism). When the only manifestation of a spider bite is an ulcerated skin lesion, clinical suspicion and differential diagnosis strongly depend on its site. We present the case of an ulcerated wound of the breast, diagnosed as a Mediterranean recluse spider bite. Case presentation: A 79-year-old woman presented a 10cm-wide soft tissue ulceration of her left breast. At first, the diagnostic hypothesis of an ulcerated cancer was ruled out. Two family members revealed a recent history of Mediterranean recluse spider bite and the same clinical diagnosis was made for our patient. A wide excision was performed, with complete resolution of symptoms. Discussion: No specific diagnostic criteria for spider bites are available. Diagnosis is usually clinical. Skin loxoscelism could be easily mistaken for cellulitis, various types of skin infections, cutaneous anthrax, vasculitis, scorpion sting, pyoderma gangrenosum, erythema migrans of Lyme disease or prurigo nodularis. A thorough anamnestic interview is fundamental to raise the diagnostic hypothesis. When possible, a biopsy is recommended and it is extremely important when the ulcer can mimic a cancer, as is the case in breast tissue. Conclusion: We recommend a wide excision of the wound after failure of conservative treatment, in order to obtain local control and to perform histological examination on a more representative specimen. Declaration of interest: The authors have no conflicts of interest to declare
    • …
    corecore